PRODUCT SKU : 1912JA001100000

PRODUCT TYPE : Circular Chart Recorders

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multi-channel field variable data collection and continuous trace visualization in process monitoring networks, the ABB 1912JA001100000 (1912JA001100000 Circular Chart Recorder) provides direct physical/electrical execution. It converts incoming analog process signals into real-time physical pen displacement and chart rotations across standard circular paper formats.

Hardware Specifications

Parameter Specification
Model 1912JA001100000
Brand ABB
Origin Sweden / Switzerland
Weight 12 lbs (5.44 kg)
Dimensions 305 mm x 254 mm x 203 mm (12 in x 10 in x 8 in)
Operating Temp 0 to +55 deg C
Power Consumption 115 VAC standard nominal supply load
Pen Configuration 2 Pen standard configuration (up to 6 independent input channels)
Input Signal Support Temperature (RTD/TC), pressure, flow, 4-20 mA / VDC analog signals
Chart Speed User-selectable rotational time profiles
Product Type Circular Chart Recorders
Environmental Compliance CE, RoHS Compliant

Channel-to-Channel Isolation and Analog Input Conditioning

The Commander 1900 series utilizes high-impedance input signal conditioning circuitry to process temperature, flow, and 4-20 mA loop variables. Channel-to-channel isolation prevents ground loop interference across active pens, maintaining signal integrity and pen position accuracy during full-scale step responses. Internal digital filters attenuate high-frequency process noise before translating loop values to servo-driven pen arm movements.

Frequently Asked Questions

Q: How should signal shielding be terminated for 4-20 mA analog input loops to prevent trace jitter?

A: Drain wires for shielded twisted-pair cables must be grounded at one single point (typically the instrument enclosure ground lug) to prevent common-mode noise interference across input channels.

Q: Can the pen calibration and chart rotation speed be adjusted directly on the unit?

A: Yes. The user-interface interface allows pen scaling adjustments, zero/span recalibration, and rotational speed selections without requiring external programming hardware.

Field Installation Guidelines

  1. Cut panel opening to specified dimensions (305 mm x 254 mm cutout clearance) and verify the panel thickness supports the 12 lbs module weight.
  2. Insert the unit through the front panel and tighten side-mounting brackets until the perimeter gasket forms a dust-tight seal.
  3. Wire the 115 VAC power input and process signal cables to the rear terminal blocks in accordance with local electrical code safety ratings.
  4. Ensure the instrument housing is bonded to protective earth (PE) using a dedicated grounding conductor prior to applying line power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more