Only 10 left - Selling fast

PRODUCT SKU : 900C70S-0360-00

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 900C70S-0360-00, also cataloged as the 900C70S CPU Module, operates as a dedicated hardware component for SIL-rated process control, function block execution, and remote I/O processing within ControlEdge HC900 platforms. Powered by a 5 VDC backplane supply drawing up to 1350 mA, the unit processes discrete and analog control loops across dual RS-485 serial interfaces and triple 10/100 Base-T Ethernet ports. It handles deterministic function block processing while maintaining real-time communication links to local and expansion racks.

Hardware Specifications

Parameter Specification
Model 900C70S-0360-00
Brand Honeywell
Origin USA
Weight 0.85 lbs (0.39 kg)
Dimensions Standard ControlEdge HC900 CPU slot footprint
Operating Temp 0 to 60 deg C
Power Consumption 1350 mA maximum at 5 VDC backplane
Functional Capability Up to 5000 function blocks (SIL-rated)
Serial Interfaces 2 x RS-485 serial ports
Ethernet Interfaces 3 x 10/100 Base-T Ethernet ports
I/O Processing Remote I/O rack expansion supported

Channel-to-Channel Isolation & DCS Network Performance

The Honeywell 900C70S-0360-00 module integrates isolated physical communication transceivers across its triple 10/100 Base-T Ethernet and dual RS-485 interfaces, decoupling central execution logic from field network noise. Internal isolation circuitry protects CPU memory registers during high-speed data transmission between remote I/O racks and process controllers. This isolated interface layer maintains signal integrity for connected analog modules handling 4-20 mA HART loop protocol field instruments and temperature sensors.

Frequently Asked Questions

Q: How is the primary power supplied to the 900C70S-0360-00 CPU module?

A: The module draws power directly from the 5 VDC system backplane bus regulated by the rack power supply, consuming up to 1350 mA under maximum processing load.

Q: Can the 900C70S-0360-00 CPU module be removed or inserted while the rack is powered?

A: Removal and insertion under power (RIUP) must comply with ControlEdge HC900 system rules; system power off is recommended during CPU hardware swaps to prevent backplane bus communication faults.

Field Installation Guidelines

  • Seat the 900C70S-0360-00 securely into the dedicated CPU slot of the HC900 controller rack, ensuring top and bottom retaining levers lock into the frame.
  • Connect shielded twisted-pair cables to the dual RS-485 ports, ensuring termination resistors are properly set at both ends of the serial bus loop.
  • Utilize Category 5e or higher shielded Ethernet cables for the three 10/100 Base-T ports to maintain isolated data links to network switches and remote I/O chassis.
  • Bond the controller rack chassis to protective earth (PE) using a dedicated grounding conductor before energizing the assembly.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more