Skip to content

What are you looking for?


You may also like

FS-SICC-0001/L24 Honeywell System Interconnection CableFS-SICC-0001/L24 Honeywell System Interconnection CableFS-SICC-0001/L24 Honeywell System Interconnection Cable
FS-SICC-0001/L24 Honeywell System Interconnection Cable
FS-SICC-0001/L24 Honeywell System Interconnection Cable
FS-SICC-0001/L24 Honeywell System Interconnection Cable

FS-SICC-0001/L24 Honeywell System Interconnection Cable


Only 10 left - Selling fast

PRODUCT SKU : FS-SICC-0001/L24

PRODUCT TYPE : System Interconnection Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell FS-SICC-0001/L24, also cataloged as the FS-SICC-0001/L24 System Interconnection Cable, operates as a dedicated hardware component for high-integrity signal routing between I/O modules and Field Termination Assemblies (FTAs) within Honeywell Safety Manager platforms.

Hardware Specifications

Parameter Specification
Model FS-SICC-0001/L24
Brand Honeywell
Origin Netherlands
Weight Approx. 1 kg
Dimensions 24 m length, 9.93 mm outer diameter
Operating Temp -20 to 85 deg C
Power Consumption Passive interconnect assembly
Conductor Size 20 x AWG 22 (0.34 mm2)
Conductor Material Copper
Voltage Rating 300 V
Impedance 120 Ohms
Shielding Double shielded for EMI protection
Connectors Pre-terminated Honeywell-compatible connectors
Compliance RoHS compliant, UL listed

Channel-to-Channel Isolation and Loop Signal Integrity

The FS-SICC-0001/L24 interconnect cable maintains physical and electrical signal segregation across its 20 AWG 22 copper conductors when bridging Safety Manager subracks to termination units. Integrated double shielding limits electromagnetic interference (EMI) and prevents capacitive cross-talk from degrading sensitive 4-20 mA HART loop protocol signals. Combined with a 120 Ohm characteristic impedance match, the assembly preserves channel-to-channel isolation parameters and minimizes attenuation across long cabinet-to-cabinet routing runs.

Frequently Asked Questions

Q: What does the "L24" suffix represent in the module part number?

A: The "L24" suffix designates the factory-precut and pre-terminated overall cable length of 24 meters, optimized for fixed interconnect distances between control racks and field termination panels.

Q: How does the double shielding construction protect analog signal transmission?

A: The double shield layer provides continuous 360-degree EMI attenuation, shielding low-voltage loop signals against high-frequency industrial noise and cross-talk from adjacent wiring channels.

Q: Can the cable connectors be re-terminated in the field if cut to a shorter length?

A: Field cutting is not recommended as the cable is factory-assembled with molded, pre-tested Honeywell-compatible connectors designed to maintain grounding continuity and strain relief.

Field Installation Guidelines

  1. Inspect pre-terminated connector housings and pin contacts for contamination or mechanical distortion prior to engagement.
  2. Maintain the minimum dynamic bend radius during installation to prevent deformation of the outer thermoplastic jacket and shield layers.
  3. Align keyed connector housings with the target I/O module and FTA header sockets, pushing straight until the retaining latches click into place.
  4. Route the cable through dedicated low-voltage instrument ducts, maintaining isolation from high-voltage AC power lines and inverter cabling.
  5. Verify shield ground grounding continuity at the panel earth bus bar according to system grounding specifications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more