Fault Caused By Improper Installation Method Of Foxboro Pressure Transmitter

  • 2021-04-26
Foxboro pressure transmitter in use, the need to understand the pressure transmitter common fault introduction, but also need to understand the transmitter measurement to check the part. 

Folkboro pressure transmitter use and installation method caused by improper problems mainly include the following aspects: pressure pipe leakage or blockage, liquid filling pipe residual gas or gas pipe residual liquid, pressure transmitter process flange deposit, the formation of dead zone measurement; The installation is not strictly in accordance with the technical requirements, and the on-site environment and installation method of the temperature transmitter do not meet the technical requirements; Primary components such as orifice plate, remote measuring joint, etc., the installation or plugging form is not correct, the pressure point is not reasonable; Pressure transmitter wiring is not correct, the power supply voltage is too low or too high, the instrument wiring terminal and the indicator head connection contact is poor.

Inspection of the measuring part of the pressure transmitter: any fault in the measuring part of the pressure transmitter will cause abnormal or no output of the pressure transmitter. Therefore, the measuring sensitive parts of the pressure transmitter should be checked first. 1. Remove the flange and check whether the isolation diaphragm of sensitive parts has deformation, oil leakage, and damage. 2. Remove the compensation plate, do not take out the sensitive parts, check the insulation resistance inserted against the shell, the insulation resistance should not be less than 100M under the condition of the voltage does not exceed 100V. 3. Connect ventilation circuit and circuit, when the pressure signal is at the upper limit of the range, close the air source, the output voltage, and reading value should be stable. If the output voltage drops, it indicates that the pressure transmitter has a leak, which can be checked out with soapy water.


ABB Honeywell GE Fanuc Yokogawa
ECC 086387-001 10024/1/1 IC695PSA040 AAI143-H00/K4A00
07 KT 97 07KT97 GJR5253000R0270 TSAI-1620M VMIVME-7750-746000 YS170-012 S4
07 KT 98 07KT98 GJR5253100R0220 TK-PRS021 VMIVME-7671-421000 YNT512D-Q12
07AI91 WT91 GJR5251600R4202 TK-PRR021 VMIPCI-5565-110000 YHC4150X-01 YHC4150X
07BT62R1 TK-PPD011 51309241-175 VIPC616 Y9612YU
07CR41-C12 TK-PPD011 V7768-320000 VI702 S1
07DC91 TK-OAV061 URRHH VI702
07DC91 GJR5251400R0202 TK-IOLI01 UR9KH VI701 S1
07DC92 TK-FXX102 UR9EH VI701
07DC92 GJR5251600R0202 TK-FTEB01 UR-8NH GE VI451-10 S2
07DC92 GJR5252200R0101 TK-FPDXX2 UR8LH GE VF702
07DI92 TDCS3000LCN UR8HH VF701 VF701 S3

ABB PLC
Allen Bradley PLC
Bently Nevada PLC
Honeywell DCS
GE Fanuc PLC
Siemens PLC
Hima DCS modules
Schneider PLC
Ovation DCS
Emerson module
Foxboro module
YOKOGAWA electric
westinghouse
High Five PLC Parts Limited

© Copyright: 2020 High Five PLC Parts Limited All Rights Reserved.

High Five PLC Parts Limited is not owner of the brands/manufacturers featured on this website. Brand names and trademarks featured are the property of their respective 

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.